Network combo lightning arrester use and description

Function and application area:
Lei Ao brand video surveillance multifunctional surge protector (network combo), used for network camera front-end equipment AC / DC power supply, network signal protection, which effectively absorb the energy shock generated by the surge, and through the grounding cable Energy is introduced into the earth. Select the corresponding product according to the operating voltage of the network camera. The multi-functional integrated design reduces the protection cost and installation difficulty, saves installation space, and greatly enhances the comprehensive protection effect of the camera.
Technical Parameters:

model

LA-IPC-12/24V

LA-IPC-220V

Power section

Rated operating voltage Un

12/24V

220V

Maximum continuous operating voltage Uc

18/30V

270V

Rated operating current IL

5A

Nominal discharge current In(8/20us)

5KA

The maximum discharge current Imax(8/20us)

10KA

Protection level Up

30V/75V

900V

Network section

Maximum continuous operating voltage Uc

Network: 8V

Rated operating current IL

300mA

Nominal discharge current In(8/20us)

5KA

The maximum discharge current Imax(8/20us)

10KA

Product specification

120×65×27mm

Protection level Up

15V

Maximum transmission rate Vs

100Mbps

Insertion loss

≤0.3dB

Response time tA

≤10ns

Working temperature T

-40~+85°C

Protective core

1, 2, 3, 6


Third, the wiring diagram


Fourth, installation instructions and precautions:
1. Before the surge protector string is connected to the protected equipment, the power must be turned off and no live operation is allowed.
2. It is installed in series between the lines of the equipment to be protected, the interface connection must be reliable, and the surge protector has the IN and OUT flags. The output is connected to the protected device. Do not reverse it. Otherwise, the surge protector will be damaged during lightning strike and the device will not be effectively protected (refer to the installation wiring diagram).
3. The grounding wire (PE) must be reliably connected to the ground of the surge protection system, and the shortest length is required to achieve the best protection effect.
4. When disconnecting the grounding wire, disconnect the device and avoid damaging the device due to the introduction of strong current such as electric welding from the ground end.
5. Connect the ground wire of the surge protector to the metal housing of the device to the ground collection bar.
6, surge protectors during use should be regularly tested, if there is a fault, it should be repaired or replaced in time to ensure the safety of the protected equipment.
7, non-professionals do not disassemble.

Igniter